TEST SETUP & TESTING 6 - 3
Test Check List
The following table summarises the required test setups.
Table 6-2 Test setup
No. Test Name Test Setup Terminal Setup Test Conditions Limits
1. IFR System
Setup and Man-
ual Test Screen
Control Channel For 450--470MHz
terminal: 2440
Traffic Channel For 450--470MHz
terminal: 2440
Time Slot 3
Country Code 262
Network Code 75
Base Colour 1
Location Area 224
Min Rx Level -110dBm
Max Tx Level 35dBm (3.2W)
Access
Parameter
-33dBm
Mobile Power 35dBm (3.2W)
Burst Type Normal
2. Base Station
Registration
RF Gen Level For 450--470MHz
terminal:
461.0125MHz
-90dBm
3. Receiver RSSI RF Gen Level 4 Cells Info
RSSI
TRACE
-90dBm
4. Transmitter
Tests
RF Gen Level Range 1
Talk Group 1
-90dBm
Burst Power 33-37dBm
Timing Error <=0.25 Symbols
Frequency
Error
-/+ 100Hz
Vector Error Max 10% RMS,
Max 30% Peak,
Max 5% Residual
5. Call Processing
Talk Back
1KHz Test Signal
Group Mode
Range 1
Talk Group 1
-90dBm
6. Call Processing
Call to Mobile
Private Mode
Private Call
Private Mode
RF Gen Level
Burst Power
-90dBm 33-37dBm
Timing Error <=0.25 Symbols
6866539D31.book Page 3 Tuesday, March 20, 2007 6:32 PM