PREREQUISITES
• Use a clean place to perform the procedure. Ensure no debris
or liquid enters into the charger.
• Use Electrostatic Discharge (ESD) Best Practices:
- Work on a hard surface such as table, counter top, or
plank of wood.
- Stand on a hard floor such as wood, or tile.
- Wear anti-static clothing.
- Use an anti-static wristband, or touch metal object
throughout the procedure.
- Use a humidifier in dry weather.
REMOVING AND REPLACING THE POCKET
INSERTS IN AN IMPRES 2 MUC
1. Unplug the power cord to the MUC.
2. Using the #2 Phillips screwdriver bit, remove the four screws
holding the rear shroud in place.
Figure 1: The four screws on the rear shroud.
MN005697A01.book Page 2 Friday, July 19, 2019 10:40 AM