25
English
Discharge or Charge
Complete
Ready to Store
LONGTERM STORAGE
xx% Rated Cap
Battery does not require
Calibration:
Steady Green
Battery requires Calibration, but
Calibration is disabled in charger:
Alternating Amber/
Green
Fault
Battery Faulted
No discharge current
Capacity too low to
complete charge
Warning:
NOT CHARGEABLE
REMOVE& REINSERT
or
CANNOT DISCHARGE
FOR LT STORAGE
or
STORE INCOMPLETE
Low Capacity:yy%
Flashing Red
Standby
Battery is waiting to rapid
charge.
Battery may be too hot,
too cold, or low voltage.
Warning:
HOT BATTERY
WAITING TO CHRGE
or
COLD BATTERY
WAITING TO CHRGE
or
VERY LOW BATTERY
WAITING TO CHRGE
Flashing Amber
Table 14: Preparing New (Never Calibrated) IMPRES 2 or IMPRES
Batteries for Long-Term Storage - Calibration Required
Status Charger Display LED Indicator
Charger Powers On
IMPRES 2
CHARGER
Green for approximately one
second
Battery Detected
IMPRES 2
BATTERY
or
IMPRES
BATTERY
Battery requires Calibration, but
Calibration is disabled by Long-
Term Storage:
Alternating Amber/
Green for four seconds
Table 13: Preparing IMPRES 2 or IMPRES Batteries for Long-Term
Storage - Calibration Not Required (Cont.)
Status Charger Display LED Indicator
MN003555A01.book Page 25 Wednesday, February 14, 2018 2:40 PM