5 - 10 SE4750 Integration Guide
POWER_MODE 0x5F (B)
0x00=Full*
0x01=Low
0x5F -
ILLUMINATION_POWER_LEVEL 0xF0 (B)
Lowest = 1
Highest Power Level = 18
Default = 13
0xF0 -
ENTER_BOOTLOADER 0x91 (A) Signature (3 bytes:
0xAA, 0x50, 0x5F)
0x91
GET_PARAM
(see Note 3 and
Table 5-4
)
0x70 (W) Param# 0x70 (W) Param# (A) Param
Data
(Note 3)
IMAGE_CAPTURE_MODE 0x73 (B)
0x00 = Continuous
0x01 = Snapshot
0x73 -
AUTO_POWER_REDUCTION 0x74 (B)
0x00=Disabled
0x01=Enabled
0x74 -
TIME_TO_LOW_POWER 0x75 (B)
0x01* - 0x0A = 10-100 ms, 10 ms
increments
0x0B - 0x14 = 100-900 ms, 100 ms
increments
0x15 - 0xFF = 1s - 235 s, 1 s increments
0x00 = 5 ms
0x75 -
WR_SCRIPT (Note 3) 0x76 (B) Script# (A) Script Data 0x76 -
EXECUTE_SCRIPT 0x77 (B) Script# 0x77 -
GET_EXTENDED_STATUS 0x79 - 0x79
PING 0x7A - 0x7A
PICKLIST_MODE 0x7B (B) #Picklist-Frames (B) #Frames 0x7B
Table 5-3
SE4750 Command and Response Formats (Continued)
Function
SE4750 Command SE4750 Response
Op SE4750 Command Data
Note1
Op
SE4750 Response
Data
Note2
Notes:
1. Every command has a 1 byte checksum (last byte of command). See
Command Checksum on page 5-4
.
2. Every response has a 1 byte status code immediately following the Opcode. See
Response Status Code
on page 5-4
.
3. These commands/responses have a variable length data field indicated by (A):Array. See
Table 5-4 on
page 5-11
for the length of the field based on the param number.