6809490A38-O September 28, 2004 35
Level 1 and 2 Service Manual Troubleshooting
Programming: Software Upgrade and Flexing
Contact your local technical support engineer for information about equipment and
procedures for flashing and flexing.
b) Transceiver board assembly
defective.
Replace the transceiver board assembly (refer
to 1c). Verify that the fault has been cleared and
reassemble the unit with the new transceiver
board assembly.
9. Vibrator feature not functioning. a) Flip assembly defective. Temporarily replace the flip assembly with a
known good assembly. If fault has been cleared,
reassemble with the new flip assembly. If fault
not cleared, proceed to b.
b) Transceiver board assembly
defective.
Replace the transceiver board assembly (refer
to 1c). Verify that the fault has been cleared and
reassemble the unit with the new transceiver
board assembly.
10. Internal Charger not working. Faulty charger circuit on transceiver
board assembly.
Test a selection of batteries in the rear pocket of
the desktop charger. Check LED display for the
charging indications. If these are charging
properly, then the internal charger is at fault.
Replace the transceiver board assembly (refer
to 1c). Verify that the fault has been cleared and
reassemble the unit with the new transceiver
board assembly.
11. Real Time Clock resetting when
standard battery is removed.
Lithium button cell in the display board
may be depleted.
Refer service to a Level 3 service center for
replacement.
12. No or weak audio when using headset. a) Headset not fully pushed home. Ensure the headset plug is fully seated in the
jack socket. If fault not cleared, proceed to b.
b) Faulty jack socket on transceiver
board assembly.
Replace the transceiver board assembly (refer
to 1c). Verify that the fault has been cleared and
reassemble the unit with the new transceiver
board assembly.
Table 3. Level 1 and 2 Troubleshooting Chart (Continued)
SYMPTOM PROBABLE CAUSE VERIFICATION AND REMEDY