EasyManua.ls Logo

Mountz HDC-35i - Auto Fastening Data Output through USB Port

Default Icon
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8. Auto fastening data output through USB port (P86)
Check mark on Enable on P86 ( auto fastening data output ), then every fastening
data will be out at every event through RS-232 without data request command.
The output data consist of 13 fastening information as below
Each data is divided by comma(,) between data.
example ) m9039001,01350,1,085,084,1700,033,0358,000,04,032,1,1,9
1. Start of Text (STX)
2. Data : m (monitoring) data
3. Serial no. : 9039001 ( 2009, March )
4. Fastening time : 1350 ms
5. Preset # : 1
6. Torque setting : 8.5
7. Fastening torque (converted torque) : 8.4
8. RPM setting : 1700 rpm
9. Fastening angle : 3.3 turn
10. Motor temperature : 35.8
11. Error code : 000 ( No error, Fastening OK ) if 301, error 301
12. Screw count # : 4 screws remained
13. Motor current : 3.2 Ampere
14. For / Rev : Fastening (1), Loosening (0)
15. Torque complete : Torque complete (1), No torque up (0)
16. Data check sum : See article 7.2.4
17. End of Text (EXT)
1080 N 11th St San Jose CA 95112
www.mountztorque.com 408.292.2214
76