NPort 5000 Series User Manual
95
Disconnection Request from the Local Site
When the NPort is in data mode, the user can drive the DTR signal to OFF, or send +++ from the local
serial port to the NPort. The NPort will enter command mode and return NO CARRIER via the serial port,
and then input ATH to shut down the TCP connection after 1 second.
NOTE
The “+++” command cannot be divided. The “+” character can be changed in register S2, and the guard
time, which prefixes and suffixes the “+++” in order to protect the raw data, can be changed in register
S12.
Disconnection Request from the Remote Site
After the TCP connection has been shut down by the remote Ethernet modem or PC, the NPort will send the
NO CARRIER signal via the serial port and then return to command mode.
AT Commands
The NPort supports the following common AT commands used with a typical modem:
No.
AT command
Description
Remarks
1
ATA
Answer manually
2
ATD <IP>:<Port>
Dial up the IP address: Port No.
3 ATE
ATE0=Echo OFF
ATE1=Echo ON (default)
4 ATH
ATH0=On-hook (default)
ATH1=Off-hook
5
ATI, ATI0, ATI1, ATI2
Modem version
reply “OK” only
6
ATL
Speaker volume option
reply “OK” only
7
ATM
Speaker control option
reply “OK” only
8
ATO
On line command
9
ATP, ATT
Set Pulse/Tone Dialing mode
reply “OK” only
10
ATQ0, ATQ1
Quiet command (default=ATQ0)
11
ATSr=n
Change the contents of S register
See “S registers”
12
ATSr?
Read the contents of S register
See “S registers”
13 ATV
Result code type
ATV0 for digit code
ATV1 for text code
0=OK
1=connect (default)
2=ring
3=No carrier
4=error
14 ATZ
Reset (disconnect, enter command mode and restore
the flash settings)
15 AT&C
Serial port DCD control AT&C0=DCD always on
AT&C1=DTE detects connection by DCD on/off
(default)
16 AT&D
Serial port DTR control AT&D0=recognize DTE always
ready AT&D1, AT&D2=reply DTE when DTR On
(default)
17
AT&F
Restore manufacturer’s settings
18
AT&G
Select guard time
reply “OK” only
19
AT&R
Serial port RTS option command
reply “OK” only
20
AT&S
Serial port DSR control
reply “OK” only
21
AT&V
View settings
22
AT&W
Write current settings to flash for next boot up

Table of Contents

Other manuals for Moxa Technologies NPort 5150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies NPort 5150 and is the answer not in the manual?

Moxa Technologies NPort 5150 Specifications

General IconGeneral
BrandMoxa Technologies
ModelNPort 5150
CategoryServer
LanguageEnglish

Related product manuals