25
Table 2: Inverter Mode Specifications
INVERTER MODEL
3KVA
Rated Output Power
3KVA/2.4KW
Output Voltage Waveform
Pure Sine Wave
Output Voltage Regulation
110/120VAC± 5%
Output Frequency
60Hz or 50Hz
Peak Efficiency
90%
Overload Protection
5s@≥150% load; 10s@110%~150% load
Surge Capacity
2* rated power for 5 seconds
Nominal DC Input Voltage
24Vdc
Cold Start Voltage
23.0Vdc
Low DC Warning Voltage
@ load < 20%
22.0Vdc
@ 20% ≤ load < 50%
21.4Vdc
@ load ≥ 50%
20.2Vdc
Low DC Warning Return
Voltage
@ load < 20%
23.0Vdc
@ 20% ≤ load < 50%
22.4Vdc
@ load ≥ 50%
21.2Vdc
Low DC Cut-off Voltage
@ load < 20%
21.0Vdc
@ 20% ≤ load < 50%
20.4Vdc
@ load ≥ 50%
19.2Vdc
High DC Recovery Voltage
29Vdc
High DC Cut-off Voltage
30Vdc
No Load Power Consumption
<50W
Saving Mode Power
Consumption
<15W