SMPPT Installation & Operation Manual Version 1.0
9
Model Category
Pmax
Voc Isc Vpmax
Ipmax
STP140D-12/
TEA
Single
Crystallin
e Silicon
Module
140W
22.4V
8.33A
17.6V
7.95A
MS140GG-02
Thin-film
Module
140W
29.0V
7.12A
23.0V
6.52A
STP190S-24/
Ad+
Single
Crystallin
e Silicon
Module
190W
45.2V
5.65A
36.6V
5.2A
NS-F130G5
Thin-film
Module
130W
60.4V
3.41A
46.1V
2.82A
The above parameters are for condition of 25°C, AM1.5 spectrum, and
1000W/m
2
illumination intensity.
Table 3-2: Solar Panels Model and Parameters
Model For 12V System
For 24V System
For 48V System
STP140D-12/T
EA
N in parallel
two in series,
N in parallel
four in series,
N in parallel
MS140GG-02 N in parallel
two in series,
N in parallel
four in series,
N in parallel
STP190S-24/A
d+
N in parallel N in parallel
two in series,
N in parallel
NS-F130G5 N in parallel N in parallel
two in series,
N in parallel
N means the quantity number required by the output current.
Table 3-3: Solar Panels Model and System Configuration Solution
3.3 Wire Sizing
To ensure
the cable temperature does not exceed the safety range, the
copper cable’s
area must be less than 4A/mm
2
. In reality application, user can
choose the
appropriate cables according to the system voltage, permitted
cable temperature, cable voltage drop and also cable material. We suggest

Questions and Answers: