EasyManuals Logo

MrCool Universal Series Service Manual

MrCool Universal Series
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
mrcool.com15
Door Control Function Selection
Under the debugging state, press the Mode button to adjust to "08" in the temperature display area. The timer
zone displays the setting state. Press the up or down arrow button to adjust. There are 2 selections:
1. Without door control function ("00" displayed)
2. With door control function ("01" displayed)
Long-Distance Monitoring or Centralized Controller Selection
Under the debugging state, press the Mode button to adjust to "10" in the temperature display area. The timer
zone displays the setting state. Press the up or down arrow button to adjust. There are 2 selections:
1. Centralized Controller ("00" displayed)
2. Long-Distance Monitoring ("01" displayed)
Long-Distance Monitoring or Centralized Controller Selection
Under the debugging state, press the Mode button to adjust to "12" in the temperature display area. The timer
zone displays the setting state. Press the up or down arrow button to adjust. There are 16 selections:
1. Compensate 32°F (0°C) ("00" displayed)
2. Compensate 33.8°F (1°C) ("01" displayed)
3. Compensate 35.6°F (2°C) ("02" displayed)
4. Compensate 37.4°F (3°C) ("03" displayed)
5. Compensate 39.2°F (4°C) ("04" displayed)
6. Compensate 41°F (5°C) ("05" displayed)
7. Compensate 42.8°F (6°C) ("06" displayed)
8. Compensate 44.6°F (7°C) ("07" displayed)
9. Compensate 46.4°F (8°C) ("08" displayed)
10. Compensate 48.2°F (9°C) ("09" displayed)
11. Compensate 50°F (10°C) ("10" displayed)
12. Compensate 51.8°F (11°C) ("11" displayed)
13. Compensate 53.6°F (12°C) ("12" displayed)
14. Compensate 55.4°F (13°C) ("13" displayed)
15. Compensate 57.2°F (14°C) ("14" displayed)
16. Compensate 59°F (15°C) ("15" displayed)
NOTE
Indoor ambient temperature compensation can be set through the wired controller (E.g. if 02 is selected,
it indicates the compensation temperature is 2°C. If the indoor ambient temperature detected by the
temperature sensor at the air return is 84.2°F (29°C), the ambient temperature after compensation is 84.2°
WIRED CONTROLLER
2

Other manuals for MrCool Universal Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MrCool Universal Series and is the answer not in the manual?

MrCool Universal Series Specifications

General IconGeneral
TypeInverter
BrandMrCool
SeriesUniversal Series
RefrigerantR410A
Phase1
Heating CapacityVaries by model
Cooling CapacityVaries by model
CompatibilityUniversal
HSPF Rating10
Voltage208/230V
Operating Temperature (Cooling)Varies by model
Operating Temperature (Heating)Varies by model
Indoor Noise Level (dB)Varies by model
Outdoor Noise Level (dB)Varies by model
Indoor Unit Dimensions (H x W x D)Varies by model
Outdoor Unit Dimensions (H x W x D)Varies by model
Indoor Unit WeightVaries by model
Warranty5 years

Related product manuals