mrcool.com15
Door Control Function Selection
Under the debugging state, press the Mode button to adjust to "08" in the temperature display area. The timer
zone displays the setting state. Press the up or down arrow button to adjust. There are 2 selections:
1. Without door control function ("00" displayed)
2. With door control function ("01" displayed)
Long-Distance Monitoring or Centralized Controller Selection
Under the debugging state, press the Mode button to adjust to "10" in the temperature display area. The timer
zone displays the setting state. Press the up or down arrow button to adjust. There are 2 selections:
1. Centralized Controller ("00" displayed)
2. Long-Distance Monitoring ("01" displayed)
Long-Distance Monitoring or Centralized Controller Selection
Under the debugging state, press the Mode button to adjust to "12" in the temperature display area. The timer
zone displays the setting state. Press the up or down arrow button to adjust. There are 16 selections:
1. Compensate 32°F (0°C) ("00" displayed)
2. Compensate 33.8°F (1°C) ("01" displayed)
3. Compensate 35.6°F (2°C) ("02" displayed)
4. Compensate 37.4°F (3°C) ("03" displayed)
5. Compensate 39.2°F (4°C) ("04" displayed)
6. Compensate 41°F (5°C) ("05" displayed)
7. Compensate 42.8°F (6°C) ("06" displayed)
8. Compensate 44.6°F (7°C) ("07" displayed)
9. Compensate 46.4°F (8°C) ("08" displayed)
10. Compensate 48.2°F (9°C) ("09" displayed)
11. Compensate 50°F (10°C) ("10" displayed)
12. Compensate 51.8°F (11°C) ("11" displayed)
13. Compensate 53.6°F (12°C) ("12" displayed)
14. Compensate 55.4°F (13°C) ("13" displayed)
15. Compensate 57.2°F (14°C) ("14" displayed)
16. Compensate 59°F (15°C) ("15" displayed)
NOTE
Indoor ambient temperature compensation can be set through the wired controller (E.g. if 02 is selected,
it indicates the compensation temperature is 2°C. If the indoor ambient temperature detected by the
temperature sensor at the air return is 84.2°F (29°C), the ambient temperature after compensation is 84.2°
WIRED CONTROLLER