Technical DataMSA
PrimaX
GB
39
6.3 Performance Specifications
6.4 List of Detectable Gases
Warm up time Combustible 95 s
OX/TOX 36 s
Storage temperature -40 °C to +70 °C
or temperature range of the sensor
Gas Default range
Selectable
range[s]
Temperature
Range
Ammonia [NH
3
] 100 ppm 50 ppm -20 – 40 °C
Ammonia [NH
3
] 500 ppm 1000 ppm -20 – 40 °C
Carbon Monoxide [CO] 200 ppm 100 ppm
500 ppm
1000 ppm
-20 – 50 °C
Chlorine [Cl
2
] 10 ppm 5 ppm -20 – 40 °C
Hydrogen [H
2
] 1000 ppm - -20 – 50 °C
Hydrogen Chloride [HCl] 30 ppm 10 ppm
20 ppm
-20 – 40 °C
Hydrogen Cyanide [HCN] 30 ppm 10 ppm
20 ppm
50 ppm
-40 – 40 °C
Hydrogen Sulphide [H
2
S] 50 ppm 10 ppm
20 ppm
100 ppm
-40 – 50 °C
Methane [CH
4
] 100 % LEL - -40 –70 °C
Nitric Oxide [NO] 100 ppm - -30 – 50 °C
Nitrogen Dioxide [NO
2
] 10 ppm 20 ppm
100 ppm
-20 – 50 °C
Oxygen [O
2
]
part no. 10112718
[recommended]
25 vol. % 10 vol. % -30 – 55 °C
Oxygen [O
2
]
part no. 10148289
25 vol. % 10 vol. % -20 – 50 °C