NOTES AND RESTRICTIONS
1. All communications are half duplex only. Only the host device or the Level Plus monitor can
transmit characters at any one time.
2. In keyboard emulation mode the Level Plus monitor can only accept characters from the exter-
nal terminal device at a rate of 10 characters per second.
3. The Level Plus monitor will not respond to external data requests during power up initializa-
tion mode or to tank numbers that are not active (i.e. not enabled).
4. The data output does not include units of measure information. The units of the data is always
controlled by the current Level Plus monitor program settings.
5. Level data output formats do not support fractional data. If monitor is programmed for frac-
tional level display, communication data outputs will be in decimal inches.