(T1L)x(A1) + (T2L)x(A2) + (T3L)x(A3) + (T4L)x(A4) + (TwT)
Substituting each variable with the respective values the equation becomes,
(1.32)x(1) + (0.65)x(1) + (0.73)x(3) + (0.58)x(1) + (5.5)
Worst case delay time to update level on all 4 gauges = 10.2 seconds.