5.2 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑ Engine is stopped and starting disabled.
Putting into operation
Item Measure
Lube oil system Check engine oil level (→ Page 134).
Coolant circuit Check coolant level (→ Page 145).
Coolant circuit If necessary, heat up coolant with coolant preheating unit if T<5 °C.
Fuel prefilter Drain water and contaminants (→ Page 119).
Battery-charging generator
drive
Check condition of drive belt (→ Page 107).
Engine Control Unit ECU Check plug connections (→ Page 163).
Engine Interface Module EIM Check plug connections (→ Page 165).
Engine Monitoring Unit EMU Check plug connections (→ Page 164).
48 | Operation | M015650/06E 2018-05
TIM-ID: 0000002689 - 004