346 – AL Open Load Cylinder A6
PV-Number:
Cause Corrective action
Disruption fault in injector wiring
for cylinder A6.
1. Check wiring of affected injector (→ Page 160).
2. Check injector.
3. Replace injector (→ Page 112).
4. Contact Service.
346 – AL Open Load Cylinder A7
PV-Number:
Cause Corrective action
Disruption fault in injector wiring
for cylinder A7.
1. Check wiring of affected injector (→ Page 160).
2. Check injector.
3. Replace injector (→ Page 112).
4. Contact Service.
346 – AL Open Load Cylinder A8
PV-Number:
Cause Corrective action
Disruption fault in injector wiring
for cylinder A8.
1. Check wiring of affected injector (→ Page 160).
2. Check injector.
3. Replace injector (→ Page 112).
4. Contact Service.
351 – AL Open Load Cylinder B1
PV-Number:
Cause Corrective action
Disruption fault in injector wiring
to cylinder B1.
1. Check wiring of affected injector (→ Page 160).
2. Check injector.
3. Replace injector (→ Page 112).
4. Contact Service.
352 – AL Open Load Cylinder B2
PV-Number:
Cause Corrective action
Disruption fault in injector wiring
to cylinder B2.
1. Check wiring of affected injector (→ Page 160).
2. Check injector.
3. Replace injector (→ Page 112).
4. Contact Service.