384 – AL Wiring TOP 4
PV-Number:
Cause Corrective action
Short circuit or wire break at
transistor output 4 plant-side
(TOP 4).
1. Check engine wiring (→ Page 160).
2. Contact Service.
390 – AL MCR exceeded
PV-Number:
Cause Corrective action
The current engine power exceeds
the continuously permissible
maximum rating.
1. Reduce power.
2. Observe any other messages.
400 – AL Open Load Digital Input 1
PV-Number:
Cause Corrective action
Open load detected at digital
input 1 of the ECU.
1. Check engine wiring (→ Page 160).
2. Check plug connections for engine governor ECU (→ Page 163).
3. Contact Service.
401 – AL Open Load Digital Input 2
PV-Number:
Cause Corrective action
Open load detected at digital
input 2 of the ECU.
1. Check engine wiring (→ Page 160).
2. Check plug connections for engine governor ECU (→ Page 163).
3. Contact Service.
402 – AL Open Load Digital Input 3
PV-Number:
Cause Corrective action
Open load detected at digital
input 3 of the ECU.
1. Check engine wiring (→ Page 160).
2. Check plug connections for engine governor ECU (→ Page 163).
3. Contact Service.
403 – AL Open Load Digital Input 4
PV-Number:
Cause Corrective action
Open load detected at digital
input 4 of the ECU.
1. Check engine wiring (→ Page 160).
2. Check plug connections for engine governor ECU (→ Page 163).
3. Contact Service.