2. Connect the test lead.
3. Note
Frequency range: 20 Hz to 60 MHz.
750 V input protection is available in all ranges.
4. Set the relative value.
Press the Rel softkey to turn on or off the relative operation. For relative operation,
the multimeter subtracts the pre-specified value of REL operation from the actual
measurement result and displays the result. See page
28, Relative Value.
Measuring Temperature
This section describes how to configure temperature measurements. Temperature
measurements require a temperature transducer probe. The supported probes are ITS-
90 K type and Pt100 sensor.
Operating Steps:
1. Enable the temperature measurement.
Press on the front panel to enter temperature measurement mode.
AC Signal