MODBUS (MFM-142 DC-M1)
Access
Type
Parameter
Register
Data Type
Float
R kWh Value *
0
2
Watt
Kilo Watt
Value
0
1
Selection
Sr.No
1
R
R
R
R
R
R
DC Voltage
DC Current
DC Watt
Watt/Kilo Watt Status
4
6
8
10
12
14
2
3
4
5
6
7
N1
*Note 1 :- In Above Energy Parameter, Energy Value
Representation shown as per below.
Example :- Actual Value = 320126789.321
Above Register Address 1 = 320126789
Below Register Address 2 = 0.321
R/W
R1 Status
R2 Status
Reset KWh 16
8
R/W
Frame Delay Time
26
13
R/W
R/W
R/W
Shunt Value
SET Point R1
Delay 1
28
30
32
14
15
16
R/W
Relay Fault mode 1 34
17
R/W
Hysterisis 1 36
18
R/W
SET Point R2 38
19
R/W
Delay 2 40
20
R/W
Relay Fault mode 2
42
21
R/W
Hysterisis 2 44
22
Float
1
R
Data Type
12
24
4800
19200
9600
38400
2400
Value
1
2
4
0
3
None
Even
Odd
Value
0
1
2
Selection
Selection
R/W
Baudrate 20
10
R/W
Parity 22
11
R/W
Address 18
9
Note :- To Reset Kwh Enter 15 Value
Slave Address :
Parity :
Read Function Register :
Write Function Register :
Frame Delay Time :
Baudrate :
Datatype :
1 to 127
None,Even,Odd
0x03 and 0x04
2400,4800,9600,19200,38400bps
Float
0x06 and 0x10
0 to 99 milli sec
Press Key to Save & Exit
PRG
Press Key
PRG
Press Key
Press Key
Press Key
PRG
PRG
PRG
Data Type -
Float
Frame Delay
Time -
0 to 100 ms
Parity -
None,Even
Odd
Slave Address -
Range:
1 to 127
Press Key For 5 Sec.
To Enter in Parameter Setting
PRG
Press Key
PRG
Baudrate -
2400,4800
9600,19200
38400 bps
Password -
(35)
R1
R1
R1
R1
R1
R1
R2
R2
R2
R2
R2
R2
OFF
ON
Value
0
1
Selection
OFF
ON
Value
0
1
Selection