EasyManua.ls Logo

MULTISPAN SQT 1044 User Manual

MULTISPAN SQT 1044
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
OPERATING MANUAL
SEQ. TIMER : 12 CHANNEL
Technical Specification
1) Model : SQT 1244
2) Display: 4 digit, Double Display
3) Input : NPN/PNP Proxy, Micro Switch.
4) Range :
1) 99.99 Sec.
2) 999.9 Sec.
3) 99.59 Min.
4) 99.59 Hrs.
5) 999.9 Hrs.
Model : SQT 1044
Panel Cutout:
(96 X 96 mm)
(92 X 92 mm)
5) Relay Status : LED indicator
1) Relay status
2) Time unit
6) Timer Mode :
1) Delayed ON
2) Delayed OFF
3) Cycle Timer
7) Output : 12 Relay
8) Power Supply : 110 To 250V AC,
50/60 Hz SMPS
Note:
1) To make parameter setting easy, menu is devided in three groups.
2) Menu 1: is used to set the parameters which are needed to change
Frequently, like On time, OFF Time
3) Menu 2: is used to set the parameters like mode, range & No. Of cycles.
4) Menu 3: is used to set the parameters Which Needed to change in rare Case
like individual & Common mode, Type of input & memory retention.
Working:
SET
SET
1) First enter in menu-3 (Short Terminal No.8 & 10 ) Then Power On.
2) Configure The instrument As per Your Application
3) Press + Key & Follow Menu as per the Application.
4) Use & Key in Menu-1
5) At Any time press key to save and exit.
6) To Change Any parameter & Key.
7) To go to next parameter, Press Key.
8) If No. key is Pressed, Menu will Automatically exit after
15 SEC. without saving.
www.multispanindia.com
PAGE - 1
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
S
M
H
SQT- 1244
SEQ. TIMER
SET
ENT
RST
ENT
RST
1 2 3 4
1 2 3 4
Question and Answer IconNeed help?

Do you have a question about the MULTISPAN SQT 1044 and is the answer not in the manual?

MULTISPAN SQT 1044 Specifications

General IconGeneral
TypeDigital Timer
DisplayLCD
Voltage Rating230V AC
Current Rating16A
Number of Programs8
Time Setting Range1 minute to 168 hours
Battery BackupYes
Mounting TypeDIN Rail

Summary

Technical Specification

Model

Specifies the model number of the sequential timer as SQT 1244.

Display

Details the display type, which is a 4-digit, double display.

Input Types

Lists supported input types: NPN/PNP Proxy and Micro Switch.

Time Ranges

Defines the available time ranges for the timer operations.

Timer Modes

Outlines the supported timer modes: Delayed ON, Delayed OFF, and Cycle Timer.

Output Configuration

Specifies the output type as 12 relays.

Power Supply Requirements

Details the power supply requirement: 110 To 250V AC, 50/60 Hz SMPS.

Menu-2 Operation

Common vs. Individual Mode

Distinguishes between 'Common' mode (all channels same) and 'Individual' mode.

Menu-3 Operation

Mode Configuration (Common/Individual)

Configures 'Common' mode for uniform channel settings or 'Individual' for unique settings.

Connection Terminal Diagram

Related product manuals