SPECIFICATIONS AND HARDWARE INFORMATION
8 Conduit
®
AP MTCAP2-L4E1-868-002 and MTCAP2-868-002 User Guide
Specifications
Category Description
General
Standards LoRaWAN 1.0.2 specifications
LTE FDD Cat 4, 3GPP release compliant (-L4E1 models only)
HSPA+ with GPRS fallback (-L4E1 models only)
RAM 256MB
Flash 256MB
Radio Frequency
ISM Band 868 MHz ISM band for Europe
4G/LTE 4G: B1, B3, B7, B8, B20, B28A (-L4E1 models only)
3G 3G: B1, B3, B8 (-L4E1 models only)
2G 2G: B3, B8 (-L4E1 models only)
Physical Description
Weight 0.4 kg
Dimensions Refer to Mechanical Drawings for Dimensions.
Chassis Type PC-ABS
Environment
Operating Temperature
1
-0° C to +70° C
Storage Temperature -40° C to +85° C
Humidity 20%-90% RH, non-condensing
Power Requirements
Operating Voltage 5Vdc, 1.4A
PoE Standard IEEE 802.3at
PoE Input Power 38-57 Vdc
LoRa ERP
2
13.3 dBm ERP for low power channels, maximum 14 dB.
25.8 dB for high power channels, maximum 27 dB.
Certifications and Compliance
EMC and Radio
Compliance
CE Mark, RED (EU)
Safety Compliance IEC 62368-1 2nd Ed
1
UL listed at 40° C, limited by AC power supply. Product has been tested to +70° C excluding power supply.
2
Determined using the internal LoRa antenna of 0.85 dB gain. If using an external LoRa antenna, adjust levels to
ensure maximum values are not exceeded.