EasyManua.ls Logo

Multitech MultiModem MT5600ZDX - Page 52

Multitech MultiModem MT5600ZDX
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MT5600ZDX Owner's Manual
52
Register Unit Range Default Description
S9
1/10 sec 0–255 6 (0.6) Sets the time, in tenths of a second,
that the carrier must be present be-
fore the modem considers it valid
and turns on the RLSD.
S10
1/10 sec 1–255 14 (1.4) Sets the time, in tenths of a second,
that a carrier signal must be lost
before the modem disconnects.
S11
1 ms 50–255 95 Sets spacing and duration of dialing
tones.
S12
1/50 sec 50–255 50 (1sec)Defines the maximum period, in fif-
tieths of second, allowed between
receipt of the last character of the
three escape character sequence
from the DTE (escape code guard
time).
S14
General Bit Mapped Options Status. Indicates the status of com-
mand options:
Bit 0 This bit is ignored
Bit 1 Command Echo (En)
0 = Disabled (E0)
1 = Enabled (E1) Default
Bit 2 Quiet Mode (Qn)
0 = Send Result Codes (Q0) Default
1 = Do not Send Result Codes (Q1)
Bit 3 Result Codes (Vn)
0 = Numeric (V0)
1 = Verbose (V1) Default
Bit 4 Reserved
Bit 5 Tone (T) /Pulse(P)
0 = Tone (T) Default
1 = Pulse (P)
Bit 4 Reserved
Bit 7 Originate/Answer
0 = Answer
1 = Originate (Default)