Cleaning
Cleaning the machine
60 10.06.2014
¾ Wait until the contact time has elapsed (see instructions of
cleanser manufacturer).
¾ Wipe with new cloth and water of drinking quality.
¾ Inspect for dirt and cleanser residues.
¾ If necessary, perform another manual cleaning and wipe it off.
¾ Disinfect components with alcohol-based disinfectant:
¾ Thoroughly disinfect the inert gas nozzles.
¾ Wait until the contact time has elapsed (see instructions of disin-
fectant manufacturer).
Clean the machine and
the floor.
¾ Clean the floor with a rubber wiper.
¾ Dispose of the waste properly.
¾ Apply cleanser to the floor with a low-pressure foaming device.
¾ Wait until the contact time has elapsed (see instructions of
cleanser manufacturer).
¾ Rinse off the floor with water of drinking quality.
NOTICE Danger of material damage!
Penetration by foreign matter (e.g. liquids, product residue, foreign
bodies) will damage the vacuum pump.
Damage can cause faults in the machine, which in turn can result in
reject packs.
¾ Do NOT spray directly on the covers of the suction openings in
the chamber.
¾ Manually clean the entire machine, including the table, with clean-
ing solution.
¾ Only clean the viewing window in the chamber lid manually
with a soft cloth or a soft brush.
¾ Wait until the contact time has elapsed (see instructions of
cleanser manufacturer).
¾ Wipe with new cloth and water of drinking quality.
¾ Inspect the entire machine and the floor for dirt and cleanser resi-
dues.