IMC08 Maintenance Manual
Version 1.01
Figure 3-19 Start the CIS Calibration
6) After the machine finishes, just take remove the calibration paper out, close both covers, and turn off machine.
7) Finally, turn on the machine to finish the CIS calibration.
3.6. Back to Default Setting
After fine tuning the screw and CIS calibration, if there are still some errors or the counting is still not correct,
returning to the factory default setting mode is required.
1) On the main menu, choose the service menu with the password “9999”, as shown in the following figures.
Then choose “Back to Default Setting.”
Figure 3-20 Service Menu
Figure 3-21 Default Setting Interface
2) After pressing start, the IMC08 will reset all the changed settings beforesettings to factory default.
Figure 3-22 Default Setting Guide
3) The processing wheels and rollers in the IMC08 will run for a while.