Use the product LEDs to troubleshoot any issue.
LED Description Diagnosis
Power LED. Power is applied.
Should be green
Connectivity to RLINK One
No light: No modem installed
Red: Modem installed but no
connectivity
Green LED: OK
LAN signal
No light: No modem installed
Red: Modem installed but no
connectivity to house
Green Blinking LED: OK
Cell phone modem
No light: No modem installed
Red: Modem installed but no
connectivity
Green: OK
Telephone line
No light: No modem installed
Red: Modem installed but no
connectivity
Green: OK
Web connectivity: Tests connection
to the application.
No light: No physical connection
Red: No connectivity
Green: OK
Active alarm
Off: No active alarm(s)
On: Active alarm
Battery
Red: Battery is disconnected
Red Blinking: Battery is not
charging (consult with dealer
immediately)
Green Blinking LED: Battery is
charging
Green: Battery is charged