© Munters AB, 2020 Trio 35
8
Appendix B: IT Setup
The following information is intended for the IT specialist/ISP personnel setting up the
internet network between the Communicator 2.0 and Trio Controllers.
IT Setup
LAN Cable Information
Typical Setups
8.1
IT Setup
Communicator 2.0 and Trio controllers must be on same subnet LAN.
o
Employ a standard home router, using the default settings, and all devices on
the same router.
o
On the local network, Communicator 2.0 and Trio must have same the subnet
mask (subnet mask must be 255.255.255.0.
o
Three first sections of the Communicator 2.0 and Trio IP address must have
the same numbers (i.e 192.168.1.x).
o
Network must be IPv4.
NOTE Munters recommends have a dedicated subnet for the Communicator 2.0/Trio
network.
The local network can employ a firewall on condition that the following ports are
open:
o
Zero-configuration networking (zeroconf)
o
RabbitMQ
o
MQTT
o
AMQPT
o
15672
o
1883
o
4200
o
UDP port 5353
o
UDP port 1900
o
TCP port 3689
o
5355
o
1883 MQTT
Communicator 2.0 has a built-in firewall; all outgoing ports are closed. Incoming
ports 8- and 443 are open.