EasyManua.ls Logo

Nabco Opus Control - SECTION 9.3: Recycle Count Reset

Nabco Opus Control
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15 of 32
www.NabcoEntrances.com OpusControlWiringandProgrammingInstallaonManual
Rev. 10-20-17 P/N C-00139
SECTION 9.3: Recycle Count “Reset
Opera on Cnt
0 cnt
Open Recycle Cnt
0 cnt
Close Recycle Cnt
0 cnt
Latest Rcycl Posi on
C1 0 Op 0
Clear Recycle Cnt
0
If you don/t know
the passcode,
Keep Pushing Switch,
Return to Normal mode
11
20
10
12
DN 1630
UNIT SPECS
Passcode
Go to Se ng menu
Stroke Learning
Yes No
Push and Hold
Rotary Dial (2 Sec.)
LEVEL 1
LEVEL 2
1. Rotate Dial to select
"Go to Se ng menu".
2. Push Rotary Dial
Se ng Category
LEVEL 3
History Se ng
Push Rotary Dial
Opera on Cnt
0 cnt
Open Recycle Cnt
2 cnt
Close Recycle Cnt
0 cnt
Latest Rcycl Posi on
C1 0 Op 0
11
20
10
12
Push and Hold
Rotary Dial (2 Sec.)
11
20
10
12
Enter Passcode
0045
Clear Recycle Cnt
0045
If you don/t know
the passcode,
Keep Pushing Switch,
Return to Normal mode
11
20
10
12
LEVEL 4
1. Rotate Dial to
select "History Se ng".
2. Push Rotary Dial

Other manuals for Nabco Opus Control

Related product manuals