Opus Control Wiring and Programming Installaon Manual www.NabcoEntrances.com
P/N C-00139 Rev 10-20-17
CHAPTER 10: FOLD DOOR WIRING DIAGRAMS
SECTION 10.1: Switches and Sensors
DN 1341
1 12VDC +12VDC
2GND Common for 12V and Signals
361Interior Ac va on
462Exterior Ac va on/Programmable Input
56BSwing Door Con nuous Safety (door mounted, swing side Safety Sensor)
Slide Door Holding Beam
6SWL Swing Door Safety with Lockout (overhead, swing side safety sensor)
Slide Door Sidelite Sensor
7Out1Programmable Output
8 BA
Break-out, Used mainly for sliding doors, can be used for ON/OFF with swing doors.
9 SQ Sequential activation. Signal to open, Signal to close.
10 H Programmable input
11
M0 Mode 0, When grounded, puts door into "One-W
ay" Mode, ("Hold-Open" when grounded with M1)
12 M1 Mode 1, When grounded, puts door into "Night" Mode, ("Hold-Open" when grounded with M0
)
13 Out2 Aux. Output 2, Programmable output, closes to GND
14 GND Ground (common) for all above signal
s
ROCKER SWITCH
ONE WAY
AUTO
ON
OFF
HOLD OPEN
A-01048
1413121110
98
N.O. BREAK-OUT SWITCHES
RED to pin 14
WHITE to pin 12
BLUE to pin 8
BLACK to pin 11 on Opus
1
2
3
4
5
ACUVISION
ACUSENSOR
FOLD SIDE
APROACH SIDE
FOLD SIDE
RED
WHITE
BLACK
GREEN
RED
BLUE
BROWN
WHITE
14-10823-01
ACUSENSOR HARNESS
M-01167
ACUVISION HARNESS
M-01730
14-8902
ACUSENSOR
14-8902
ACUSENSOR HARNESS
M-01167
RED
WHITE
BLACK
GREEN
1
2
2
3
1
2
2
4
1
2
2
6
To Pin # on Opus Control
7
6
54
321