EasyManua.ls Logo

Nabco Opus Control - Simultaneous Pair Full Automatic with Monitoring

Nabco Opus Control
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28 of 32
Opus Control Wiring and Programming Installaon Manual www.NabcoEntrances.com
P/N C-00139 Rev 10-20-17
SECTION 11.11: Other
DN 1333
1413121110
98
7
6
54
321
1413121110
98
8 BA Break-out, Used mainly for sliding doors, can be used for ON/OFF with swing doors.
9 SQ Sequential activation. Signal to open, Signal to close.
10 H Programmable input
11 M0 Mode 0, When grounded, puts door into "One-Way" Mode, ("Hold-Open" when grounded with M1)
12 M1 Mode 1, When grounded, puts door into "Night" Mode, ("Hold-Open" when grounded with M0)
13 Out2 Aux. Output 2, Programmable output, closes to GND
14 GND Ground (common) for all above signals
For connecting to a
second Opus for
Sim-Pair, Astragal,
Sequencing
1413121110
98
10
14
Example of a switch being used to turn
on/off Power-Close and Hold Closed.
Programmable input "H" (terminal 10)
would be set "Spring Close Only".
To see other options for the
programmable input, see programming
and input settings.
PROGRAMMABLE INPUT
SECTION 11.12: Motor Wiring
 11.12.1 GT300/400/500/600/1400
DN 1315
ENCODER MOTOR WIRING
NONENCODER WIRING
Handing Harness
(Right Hand Units)
To Opus ControlTo Motor
To Motor
Non-Encoder
Adapter Harness
To Opus Control
Motor
Harness
To Door
Posi on Switches
Brake Module
 11.12.2 GT710/8710
DN 1327
ENCODER MOTOR WIRING
NONENCODER WIRING
Non-Encoder Adapter Harness
To Motor
To Motor
To Opus Control
2
1
1
2
To Door Posi on
Switches
Motor Harness
2
1
1
2
Motor Fuse
To Opus Control
Motor Harness
Motor Fuse

Other manuals for Nabco Opus Control