EasyManuals Logo

NAPCO Gemini GEM-P1632 Installation Instructions

NAPCO Gemini GEM-P1632
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
L
NAPCO Security Systems
X
GEM-P1632 Installation Instructions
WI808F 8/03
!
Page 19
Compatibility Number (Not Applicable)
THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P1632
CONTROL PANEL.
Press the
R button to continue or press the C button to exit.
EZM Address
The keypad's internal EZM (Expansion Zone Module) may be utilized to
provide four additional wired zones. Whether used alone or in conjunction
with optional GEM-EZM series modules or other keypad EZMs, it must be
assigned a unique address (or Group number, see Keypad Programming
Workbook) similar to its keypad address. If no other EZMs are to be used, designate the keypad as Group “01” at the
EZM ADDRESS 00
” display. In multiple-EZM systems, enter an assigned group number “01” through “06”. (Each EZM
must have a unique assigned group number, starting with “01” and proceeding consecutively.) Press the
U
button to
save. Press the
R
button to continue or press the
C
button to exit.
Zone Response
The normal loop response of each keypad expansion zone is 750mS,
however the response time of any zone can be reduced to 50mS as
follows.
1. Of the following, circle the number(s) in parentheses associated with the
zone(s) to be changed:
Zone 1=(1); Zone 2=(2); Zone 3=(4); Zone 4=(8)
2. Add up the circled numbers.
3. At the keypad, enter the sum as a two-digit number “01” through “15” on the display, then press the
U
button.
Example. Change Zones 2, 3 and 4 to 50mS response.
1. Circle numbers for Zones 2, 3 and 4: (2), (4) and (8).
2. Add up the circled numbers: 2 + 4 + 8 = 14.
3. Enter “14” at the keypad, then press the
U
button.
Press the
R
button to continue or press the
C
button to exit.
Program Control Message (Not Applicable)
THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P1632
CONTROL PANEL.
Press the
R button to continue (the display will loop back through
selections, for changes) or press the
C button to exit the Keypad Configuration Mode (display will read “
01 OUT OF
SYSTEM
”). Then replace Jumper JP1 across Pins 1–2 (top two).
New
Compat # 0000
EZM Address
01
Zone Response
00
Program Control
Message # ?
Keypad Configuration Mode

Other manuals for NAPCO Gemini GEM-P1632

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO Gemini GEM-P1632 and is the answer not in the manual?

NAPCO Gemini GEM-P1632 Specifications

General IconGeneral
BrandNAPCO
ModelGemini GEM-P1632
CategoryControl Panel
LanguageEnglish

Related product manuals