X
GEM-P1632 Installation Instructions
L
NAPCO Security Systems
WI808F 8/03
!
Page 46
Keypad Programming Modes: Dealer Mode
DEALER MODE
CONDITION DISARMED ARMED KEYPAD MESSAGE
If Zone Faults? * Y N/A
DISPLAY ZN FAULTS
If Zone Bypasses? Y Y
DISPLAY ZN BYPASSED
Always * Y Y
DISPLAY ZN DIRECTORY
If Fire Alarm? Y Y
DISPLAY FIRE ALARM
If Fire Trouble? Y Y
DISPLAY FIRE TROUBLE
Always Y N/A
ACTIVATE/DEACTIVE CHIME
If Sensor Watch / If System Trouble? Y Y
RESET SYSTEM TRBL
Always Y N/A
ACTIVATE FAULT FIND
After Test Timer Y Y
ACTIVATE DIALER TEST
Always Y N/A
TO ARM IN 1-4HRS/PRESS 1-4
If Auto Arm? Y N/A
TO DELAY AUTO ARM/PRESS 1-4
Always Y N/A
ACTIVATE PROGRAM
Always Y Y
ACTIVATE DOWNLOAD
DEALER MODE
Enter Dealer Code
Press
R
button
Repeat
Press
C
button to Exit at any time
N/A means Not Available.
Repeat
EASY MENU PROGRAM
MODE (See Next Page)
Factory Default:
456789
12
4
3
56
7890
A
B
C
D
E
F
G
NEXT/YES
PRIOR/NO
AREA
Scroll Down
Scroll Up
Exit
Yes
No
For "Classic" Keypads
12
4
3
56
7890
A
B
C
D
E
F
G
NEXT/YES
PRIOR/NO
AREA
Scroll Down
Scroll Up
Exit
Yes
No
R
For "K Series" Keypads