X GEM-P3200 Programming Instructions
Page 7
WI1184B 2/06
24 Hour Zones in Area 1 (New Program Only)
Enter the zone numbers of zones to be used as 24 Hour zones.
Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
Press U to save and repeat for any additional zone(s); press the NEXT/YES button to proceed.
NOTE: 24 Hour Zones will automatically be programmed as audible (Burg Output).
Chime Zones in Area 1 (New Program Only)
Enter the zone numbers which are to be used as Chime Zones.
Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
NOTE: A chime time of 2 seconds will be automatically programmed.
Chime 2 Zones in Area 1 (New Program Only)
Enter the zone numbers which are to be used as Chime 2 Zones.
Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
NOTE: A chime time of 2 seconds will be automatically programmed.
Chime 2 zones give a distinct pulsating tone when zone is faulted.
Exit/Entry2 Zones in Area 1 (New Program Only)
Enter the zone numbers of zones to be used as Exit/Entry zones.
Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
Press U to save and repeat for any additional zone(s), press the NEXT/YES button to proceed.
NOTE: An Entry Delay Time of 30 seconds and an Exit Delay Time of 60 seconds will automatically be programmed.
50 mS Loop Response Zones (New Program Only)
Enter the zone numbers of zones to have a 50mS loop response.
Valid entries are from 01 to 08. Directly enter each zone number, including leading zeros.
Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed. Note: Only panel
zones 01-08 can be programmed for Quick Loop Response. All other zones can be programmed via their respective
EZM's (hardwire).
Note: 750mS is required for Loop Response time in UL installations.
Aux Output Activated on Alarm Zones (New Program Only)
Enter the zone numbers of zones to activate the Aux Output upon alarm.
Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
Press U to save and then repeat for any additional zone(s); press the NEXT/YES button to proceed.
NOTE: An Aux Output Timeout of 15 minutes will automatically be programmed.
Sensor Watch Zones (New Program Only)
Enter the zone numbers of zones to be Sensor Watch zones.
Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
NOTE: A Sensor Watch Time of 24 hours will automatically be programmed.
Keypad Sounder On Alarm Zones (New Program Only)
Enter the zone numbers of all zones to activate the Keypad Sounder upon alarm.
Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
Auto Bypass Re-entry Zones (New Program Only) (Not evaluated by UL)
Enter the zone numbers of zones to be Auto Bypass Re-entry zones.
Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
Auto Bypass Re-entry Zones allow the system to be armed with the zone faulted but come back into the system (armed)
when the zone is subsequently closed.
(Direct Entry)
Ent24H
Zn#XX
(Direct Entry)
EntCZ1
Zn#XX
(Direct Entry)
EntCZ2
Zn#XX
(Direct Entry)
EntEE2
Zn#XX
(Direct Entry)
Ent50m
Zn#XX
(Direct Entry)
EntAux
Zn#XX
(Direct Entry)
Ent SW
Zn#XX
(Direct Entry)
EntKPS
Zn#XX
(Direct Entry)
EntAUB
Zn#XX
GEM-RP2ASE2/GEM-K2AS KEYPAD EASY PROGRAM MENU

Table of Contents

Other manuals for NAPCO Gemini GEM-P3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO Gemini GEM-P3200 and is the answer not in the manual?

NAPCO Gemini GEM-P3200 Specifications

General IconGeneral
BrandNAPCO
ModelGemini GEM-P3200
CategoryControl Panel
LanguageEnglish

Related product manuals