L NAPCO Security Systems
X GEM-P3200 Programming Instructions
Page 7
WI1184B 2/06
24 Hour Zones in Area 1 (New Program Only)
• Enter the zone numbers of zones to be used as 24 Hour zones.
• Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
• Press U to save and repeat for any additional zone(s); press the NEXT/YES button to proceed.
NOTE: 24 Hour Zones will automatically be programmed as audible (Burg Output).
Chime Zones in Area 1 (New Program Only)
• Enter the zone numbers which are to be used as Chime Zones.
• Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
• Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
NOTE: A chime time of 2 seconds will be automatically programmed.
Chime 2 Zones in Area 1 (New Program Only)
• Enter the zone numbers which are to be used as Chime 2 Zones.
• Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
• Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
NOTE: A chime time of 2 seconds will be automatically programmed.
Chime 2 zones give a distinct pulsating tone when zone is faulted.
Exit/Entry2 Zones in Area 1 (New Program Only)
• Enter the zone numbers of zones to be used as Exit/Entry zones.
• Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
• Press U to save and repeat for any additional zone(s), press the NEXT/YES button to proceed.
NOTE: An Entry Delay Time of 30 seconds and an Exit Delay Time of 60 seconds will automatically be programmed.
50 mS Loop Response Zones (New Program Only)
• Enter the zone numbers of zones to have a 50mS loop response.
• Valid entries are from 01 to 08. Directly enter each zone number, including leading zeros.
• Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed. Note: Only panel
zones 01-08 can be programmed for Quick Loop Response. All other zones can be programmed via their respective
EZM's (hardwire).
Note: 750mS is required for Loop Response time in UL installations.
Aux Output Activated on Alarm Zones (New Program Only)
• Enter the zone numbers of zones to activate the Aux Output upon alarm.
• Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
• Press U to save and then repeat for any additional zone(s); press the NEXT/YES button to proceed.
NOTE: An Aux Output Timeout of 15 minutes will automatically be programmed.
Sensor Watch Zones (New Program Only)
• Enter the zone numbers of zones to be Sensor Watch zones.
• Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
• Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
NOTE: A Sensor Watch Time of 24 hours will automatically be programmed.
Keypad Sounder On Alarm Zones (New Program Only)
• Enter the zone numbers of all zones to activate the Keypad Sounder upon alarm.
• Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
• Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
Auto Bypass Re-entry Zones (New Program Only) (Not evaluated by UL)
• Enter the zone numbers of zones to be Auto Bypass Re-entry zones.
• Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
• Press U to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
• Auto Bypass Re-entry Zones allow the system to be armed with the zone faulted but come back into the system (armed)
when the zone is subsequently closed.
(Direct Entry)
Ent24H
Zn#XX
(Direct Entry)
EntCZ1
Zn#XX
(Direct Entry)
EntCZ2
Zn#XX
(Direct Entry)
EntEE2
Zn#XX
(Direct Entry)
Ent50m
Zn#XX
(Direct Entry)
EntAux
Zn#XX
(Direct Entry)
Ent SW
Zn#XX
(Direct Entry)
EntKPS
Zn#XX
(Direct Entry)
EntAUB
Zn#XX
GEM-RP2ASE2/GEM-K2AS KEYPAD EASY PROGRAM MENU