W415-0973 / B / 08.28.13
51
IOM
20.0 WIRE DIAGRAM FOR SINGLE STAGE
FURNACE WITH X13 ECM, AND PSC
INDUCER
120 VAC
GAS VALVE
24 VAC
WHITE
BLACK
WHITE
BLACK
WHITE
BLACK
IGNITOR
24 VAC
BLACK
YELLOW
YELLOW
BLACK
RED
RED
RED
RED
PURPLE
RED
RED
HIGH LIMIT
24 VAC
LEFT ROLLOUT
24 VAC
FLAME SENSOR
24 VAC
RIGHT ROLLOUT
24 VAC
IND. -0.80
PRESSURE SWITCH
24 VAC
FMC -0.15
PRESSURE SWITCH
24 VAC
C1
G173-R STYLE GROMMET
H24.2
PSC MOTOR
BLACK
WHITE
GREEN
JUNCTION
BOX
120 VAC
W = WHITE
R = RED
Y = YELLOW
BU = BLUE
BK = BLACK
24 VAC
+ 120 VAC -
P1
P2
NEUTRALS
HUM
L1
XFMR
EAC
PARK
PARK
45
W
R
Y
BK
BU
60
W
Y
BU
BK
R
80
W
BK
BU
Y
R
100
W
BU
BK
Y
R
120
W
BK
BU
Y
R
HEAT
HI COOL
201
PSC MOTOR
1
5
5
7
7
8
8
6
6
3
3
4
4
2
2
1
1
BLACK
BLACK
WHITE
WHITE
H24.1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Napoleon 9600 Series and is the answer not in the manual?

Napoleon 9600 Series Specifications

General IconGeneral
AFUE Rating96%
Blower TypeVariable speed
Gas ValveModulating
Ignition SystemHot surface ignition
Fuel TypeNatural gas or propane
Heat ExchangerStainless steel
Blower MotorECM
Heat Exchanger WarrantyLifetime limited
Parts Warranty10 years
Vent Size2" or 3"
Stages2-stage
Heating Capacity40, 000 - 120, 000 BTU

Related product manuals