2. BIPT600 BUILT-IN INSTRUCTIONS
This grill is designed for masonry, non-combustible enclosures only, and must be installed and serviced by a qualified installer to
local codes.
1. Attach side mounting brackets and side trim pieces to each side of the grill using 1/4-20 x 1/2" screws (n570-0026).
2. Mount the lower front trim to the bottom front edge of the opening (fasteners not included).
3. Lay the rear trim piece across the back of the opening. To keep it in place, a dab of silicone may be applied to each wing of the
rear trim.
4. Lower the unit in place, and connect the gas supply line to the fitting at the end of the manifold.
5. The unit must be secured in place (fasteners not included). This can be accomplished by mounting the left and right trim pieces
to the sides of the opening to the sides of the cabinet.
6.The entire installation must be leak tested before operating the unit.