8
N415-0704-AU REV - MAY 11.22
This unit includes an internal regulator which stabilizes the gas
pressure and improves grill performance. This regulator cannot
be adjusted. There is a pressure tap located on the side of the
regulator. It can be used by a qualied service person when
servicing the grill to determine if the regulator is funconing
properly. The screw within the pressure tap must always be
kept ght, except when performing a pressure test on the
regulator (qualied service personnel only).
Natural Gas Hook-Up
The installaon must be performed by a licensed gas er in accordance with AS/NZS 5601, and all
connecons must be leak tested before operang the grill.
This natural gas grill is supplied with a 3000 mm supply hose with an inside diameter of 12 mm, complete
with bayonet ngs, designed for natural gas, and cered for outdoor use.
Aach the ex connector from the manifold assembly to the natural gas regulator supplied as illustrated in
the Natural Gas Hose Aachment diagram. Tighten using two wrenches. (Do not use thread sealer/pipe
dope.)
: The gas grill is designed to operate at a test point pressure of 1.00 kPA and must be checked aer
installaon by turning all burners on and measuring at the regulator outlet test point provided.
WARNING!
•
•
•
•
•
•