Facing and/or fi nishing material must never overhang into the fi replace opening.
Do not distort or force the frame kit components.
When using a rough fi nish material (i.e. stone), maintain a ¼” - ½” border from the framing
components.
MINIMUM ENCLOSURE CLEARANCES
Minimum clearance to combustible construction from fi replace
and vent surfaces:
Combustible framing:
- 0 “ to stand-offs
Non-combustible fi replace fi nishing:
- 4 “ from the sides of fi replace opening
- 22
3
/
8
“ to the top of fi replace opening
Combustible fi replace fi nishing:
- 0 “ to rear and sides
- 2” all around the vent pipe
- 22
1
/
4
“ recessed depth
- 72 “ from bottom of unit to enclosure top
- 72 “ from bottom of unit to ceiling
FIGURE 32
HORIZONTAL VENT SECTIONS: A minimum clearance of 2” all around
the vent pipe on all horizontal runs to combustibles is required. Use
restop spacer W010-1799 (supplied).
VERTICAL VENT SECTIONS: A minimum of 1” all around the vent pipe
on all vertical runs to combustibles is required except for clearances in
replace enclosures. Use fi restop spacer W500-0096 (not supplied).
!
WARNING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Napoleon Tureen GD82NT-T and is the answer not in the manual?

Napoleon Tureen GD82NT-T Specifications

General IconGeneral
BrandNapoleon
ModelTureen GD82NT-T
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals