16. Slightly push the walking deck forward toward the console, and then push the Deck Release Handle until the locking tube releases and you can
pull the walking deck away from the console. Hold up the rear of the walking deck, and move to the side of the machine.
Keep clear of the movement path of the walking deck.
17.Thehydraulicliftissetuptodropgradually.Holdontothewalkingdeckuntilapproximately2/3ofthemovementdown.Makesurethatyouuse
proper lifting technique; bend your knees and keep your back straight. Be aware that the walking deck can possibly drop quickly in the last part of the
movement.
18. Re-install all remaining parts that were removed in reverse order.
19.AttachthepowercordandturnontheTreadmillbyippingthepowerswitchtoON.
20. From the Power Up (or Welcome) screen, push and hold down the PAUSE/STOP button and Right arrow button for about 5 seconds to go into
the Console Setup Mode. The Console display will show the Date prompt with the current setting.
21. Push the OK button 4 times until the Console displays the TOTAL RUN HOURS screen.
22. Push and hold down the PAUSE/STOP button and Right arrow button for about 5 seconds to go into the Engineering Mode. The Console display
will show the current Firmware Version.
23. Push the Down arrow button 4 times until the Console displays “RUN MCB CAL”.
Be sure the area around the Treadmill is clear of all bystanders, children and pets. Be sure there is nothing on or under the Walking
Belt, or near the Treadmill.
24. With the area clear, push the OK button. The calibration procedure will begin by automatically moving the Walking Belt and lifting the Deck
through the full range of incline motion.
Be sure not to touch or allow anyone else to touch the machine while calibration is occurring.
25. When calibration is complete, the Console will display “done” for a few seconds, and then return to the “RUN MCB CAL” option.
26. Flip the power switch to OFF. Calibration is now complete for the machine.
27. Final Inspection
Inspect your machine to ensure that all hardware is tight and components are properly assembled.
Do not use until the machine has been fully assembled and inspected for correct performance in accordance with the Owners
Manual.

Table of Contents

Other manuals for Nautilus T618

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nautilus T618 and is the answer not in the manual?

Nautilus T618 Specifications

General IconGeneral
FoldableYes
Bluetooth ConnectivityYes
Cooling FanYes
Running Surface20" x 60"
Incline Range0% to 15%
Speed Range0 to 12 MPH
DisplayLCD
Programs26
Heart Rate MonitoringYes
Weight Capacity350 lbs
AudioYes
Dimensions57.6" H

Related product manuals