EasyManua.ls Logo

NCR 7870 - Calibration Procedure

NCR 7870
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5: Calibration 5-3
Calibration Procedure
Section 1: Exercising the Scale
Tools
One of the following:
Whole Pound Weight Set (P/N 998-0633009)
Fractional Pound Weight Set (P/N 998-0633012)
Kilogram Weight Set Obtain locally
Instructions
You must exercise the scale before performing a calibration.
1.
Select appropriate Weight Feature for your Scanner/Scale.
Weight Feature Total Weight on Top Plate
9.995 kg 0.0 kg 2.5 kg 5.0 kg 10.0 kg 5.0 kg 2.5 kg 0.0 kg
13.995 kg 0.0 kg 2.5 kg 5.0 kg 15.0 kg 5.0 kg 2.5 kg 0.0 kg
30.0 lb. 0.0 lb. 5.0 lb. 15.0 lb. 30.0 lb. 15.0 lb. 5.0 lb. 0.0 lb.
2.
Add and remove weights to your scale in order given in chart.
This is a building procedure in which you start with no weight (0)
and sequentially add and remove weight to obtain the values
shown in the chart.
3.
Go through procedure four times.
4.
Go to Section 2
: Accessing the Calibration Switch
.

Table of Contents

Related product manuals