NCR SelfServ 22e ATM Site Preparation
12 B006-6902-D000
MANOEUVRING THE ATM INTO POSITION
Ensure that doorways and corridors leading to your point of installation are wide enough
to allow the package to pass through, or make arrangements to unpack the ATM in an area
with sufficient access and then move it to the installation site. Also make sure that any
corridors can support the weight of the ATM. Refer to page 39 for the maximum weight of
the ATM and its floor loading.
Front Access
Packaged ATM
The following table gives the minimum dimensions for doorways, corridors with right
angle corners and the space required to rotate on its axis a packaged ATM.
Note 1: The dimensions assume the ATM is being moved using equipment that does not
extend beyond the ATM or packaging.
Note 2: A surrounding clearance of 6 mm (0.24 in.) has been allowed in the figures.
Pallet, carton and lid
Pallet and carton or
pallet without carton
A Doorway or straight corridor 735 mm
(28.94 in.)
732 mm
(28.82 in.)
B Corridor with corner 841 mm
(33.00 in.)
839 mm
(33.03 in.)
C Rotation about centre 1166 mm
(45.91 in.)
1165 mm
(45.87 in.)