NCR SelfServ 22e ATM Site Preparation
B006-6902-D000 39
REQUIREMENTS FOR THE FLOOR
The ATM is suitable for mounting on a concrete or other non-combustible surface only.
Floor Covering
An antistatic floor covering should be used and must be of a type that will not generate
dust or fluff. The surface on which the ATM is to be sited should be level and even. In
locations where the floor may be uneven, it is recommended that a steel plate is used under
the ATM.
Floor Loading
The ATM must be installed on a floor capable of supporting the maximum weight. Only
the maximum weight should be considered as additional options may be added after
installation.
Front Access
Rear Access
CEN Grade L or CEN
Grade 1
UL 291 24 Hours Level 1 UL 291 Business Hours
Maximum weight 520 kg
(1146.6 lb.)
440 kg
(970.2 lb.)
270 kg
(595.4 lb.)
Floor loading 1714 kg/m
2
(351.1 lb./ft
2
)
1438 kg/m
2
(294.5 lb./ft
2
)
896 kg/m
2
(183.4 lb./ft
2
)
CEN Grade L UL 291 24 Hours Level 1
Maximum weight 560 kg
(1234.8 lb.)
475 kg
(1047.4 lb.)
Floor loading 1557 kg/m
2
(318.6 lb./ft
2
)
1319 kg/m
2
(270.2 lb./ft
2
)