4-8
1 2 3 4 5 6 7
AUTO
GAIN RED 244
GAIN GREEN 250
GAIN BLUE 220
OFFSET RED 90
OFFSET GREEN 85
OFFSET BLUE 82
1 2 3 4 5 6 7
OSD DESIGN 0
OSD SELECT OSM
URL 1
FIRST AUTO ON
THRESHOLD 4
6. Factory Mode Explanations
ON: Accumulated time during the reception of input signals
(LED: green)
OFF: Accumulated time in the power-saving mode and soft
power off mode (Only AC power input).
(LED: amber or off)
* The accumulated time (hours running) is reset when
FACTORY RESET is executed.
FACTORY PRESET: All data are reset to the initial values.
AUTO: Auto-adjustments for the gain and the offset.
GAIN R/G/B: It is possible to adjust the gain values of
R, G, B, respectively.
* This value use Auto contrast of user menu.
OFFSET R/G/B: It is possible to adjust the offset values of
R, G, B, respectively.
OSD DESIGN: No Used.
OSD SELECT: The OSD/OSM display is changed over for
the OSM menu.
OSM (Setting for shipment)
OSD
URL: Display or no display of URL (Internet address)
0: Not displayed
1: Displayed (WWW.NECMITSUBISHI.COM): Setting for
shipment (for North America and Europe version)
2: Displayed (WWW.NMV.CO.JP): (for Japan)
FIRST AUTO: Non touch auto adjust function switch.
ON: NTAA function enable. (Setting for shipment)
OFF: NTAA function disable.
THRESHOLD: Image detect level of auto adjust.
0: Min
16: Max
4: Initial
1 2 3 4 5 6 7
HOURS RUNNING
ON 104H 38M
OFF 224H 40M
FACTORY RESET