What to do if the NEC Electra Elite Telephone System does not recognize the IAD(8)-U( ) ETU?
- KKaren MorrisonJul 31, 2025
Ensure that the Electra Elite system is programmed for the same card type using Memory Block 7-1 (Card interface Slot Assignment) as the operating mode of the IAD(8)-U( ) ETU. For example, if the IAD(8)-U( ) ETU is in slot 3 of cabinet 1 and operating as a COID(8)-U10 ETU, the Electra Elite IPK II system must be programmed, using a PC or handset, for a COID(8)-U10 ETU in slot 3 of cabinet 1.