4 - 2 IPK II IAD(8)-U( ) Configuration
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 1 H.323 Trunk
SECTION 3SAMPLE SETUP PROCEDURE
To setup the IAD ETU:
1. Set the card type according to the settings specified in Table 1-2 IAD(8)-U( )
Switch Settings on page 1-3 and then install the ETU in the Electra Elite IPK II
KSU.
2. Boot up the statically assigned Host PC.
3. Connect to the IAD (8)-U( ) ETU via your Web Browser.
4. Set the IP Address, Subnet Mask, Computer Name, and Default IP parameters
in the IAD (8)-U( ) ETU configuration tab. Select "Submit" to store the new
configure information.
5. Set the parameters in the Station Settings tab. Select "Submit" to store the new
configure information.
For COID/COI modes, the incoming numbers to a particular trunk on the KSU
are mapped to the Station Settings tab dialed number.
For COID, the caller ID is the outgoing Caller Name field.
Example:
î
When the IAD (8)-U( ) ETU (COI/COID) receives 9727517646 as the
digits from the calling IAD system, it presents the call on Trunk 2. For
outgoing calls made on Trunk 2, the Gateway ETU sends the caller
name as Marketing.
6. Set the parameters for outgoing calls in the Address Translation tab. This
information maps the dialed digits to the IP address of the receiving IAD(8)-U()
ETU.
Example:
Trunk
Number
Caller ID Dialed Number
1 Sales 9727517653
2 Marketing 9727517646
3 Station 3 102
Dialed Number Address
214 10.1.0.100