B - 2 Troubleshooting
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 1 H.323 Trunk
Question:
The Electra Elite system does not recognize the IAD(8)-U( ) ETU and displays
UNUSED for any attempt to seize the assigned trunk.
Answer:
Make sure the Electra Elite system is programmed for the same card type using
Memory Block 7-1 (Card interface Slot Assignment) as the operating mode of the
IAD(8)-U( ) ETU. For example, if the IAD(8)-U( ) ETU is in slot 3 of cabinet 1 and
operating as a COID(8)-U10 ETU, the Electra Elite IPK II system must be
programmed, using a PC or handset, for a COID(8)-U10 ETU in slot 3 of cabinet 1.
Question:
What IP Ports are needed for H.323 Trunk operation?
Answer:
For the H.323 Trunk card and the H.323 Protocol the following ports are necessary:
SECTION 3RETURNING THE IAD(8)-U( ) ETU (H.323 TRUNK) TO DEFAULT
C
ONFIGURATION
To return the IAD(8)-U( ) ETU to the default configuration:
1. Remove the IAD(8)-U( ) ETU.
2. Set DIP switches S2(1) ~ S2(8) in the ON position (factory default).
3. Replace the IAD(8)-U( ) ETU in the KSU.
4. When the bootup process is completed, the IAD(8)-U( ) ETU is restored to the
factory default package.
5. The IAD(8)-U( ) ETU Default IP Address is: 192.168.1.100. The subnet mask is
255.255.255.0.
Application
Port Numbers
Comments
H.323 Protocol 1720 TCP/UDP
H.323 Trunk Card IAD(8)-U( ) ETU 49150 Starting RTP Port