EasyManua.ls Logo

NEC NP-17CU01 - Page 16

NEC NP-17CU01
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Important Information
Radiation Range of Emitted Light by the Projector (HD: Hazard Distance)
The below table describes the radiation range of emitted light by the projector that is classified as Risk Group 3 (RG3) of
IEC62471.
Please keep within bounds for installing the projector.
Install a barrier for preventing human eyes from entering the RG3 area.
For the barrier installation position, keep horizontal safety zone over 1.5m from the RG3 area.
In case to install the projector over head, keep over 3m distance at least between the floor surface and the RG3 area.
Lens HD(m) H(m) V(m)
NP-9LS12ZM1 2.8 1.63 0.86
NP-9LS13ZM1 3.5 1.67 0.88
NP-9LS16ZM1 4.2 1.56 0.82
NP-9LS16Z1 3.7 1.81 0.96
NP-9LS20ZM1 4.7 1.21 0.64
NP-9LS20Z1 5.2 1.91 1.01
NP-9LS40Z
NP-9LS40ZM1
10.0 1.58 0.83
[Plan view]
[Side view]
RG3 range
HD
H
V
* If lens shift is utilized, please consider the shift of projected image according to the volume of lens shift.