3.15 [ 037. INFORMATION REQUEST ]
Gets the information of the projector.
Command
03h 95h 00h 00h 00h 98h
Response
4 When the command succeeds
23h 8Ah <ID1> <ID2> 62h <DATA01> - <DATA98> <CKS>
Data part
Item Description
DATA01 - 49 Projector name (NUL: termination character string).
DATA50 - 82 Reserved for the system
DATA83 - 86 Lamp usage time (seconds)
DATA87 - 90 Filter usage time (seconds)
DATA91 - 98 Reserved for the system
4 When the command fails
A3h 8Ah <ID1> <ID2> 02h <ERR1> <ERR2> <CKS>
4 Response example
When the lamp usage time is18000 seconds (5 hours)
23h 8Ah <ID1> <ID2> 62h <DATA01> - <DATA82> 50h 46h 00h 00h
<DATA87> - <DATA98> <CKS>
Lamp usage time (DATA83 – DATA86) = 18000 / 3600 = 5 hours
Information
While the usage time can be obtained in one-second units, the information is updated at one-minute intervals.