67
3.38 [ 084. INFORMATION STRING REQUEST ]
Gets the information strings (English) displayed on the projector.
Command
00h D0h 00h 00h 03h 00h <DATA01> 01h <CKS>
Data part
Item Description
DATA01 Information type
03h Horizontal synchronous frequency
04h Vertical synchronous frequency
Response
4 When the command succeeds
20h D0h <ID1> <ID2> LEN <DATA01> 01h <DATA02> - <DATA??> <CKS>
Data part
Item Description
DATA01 Information type
03h Horizontal synchronous frequency
04h Vertical synchronous frequency
DATA02 Label/information string length (excluding NUL characters)
DATA03 - ?? Label/information strings (NUL: termination character string)
4 When the command fails
A0h D0h <ID1> <ID2> 02h <ERR1> <ERR2> <CKS>