CHAPTER 4 OFFICE DATA DESIGN
Note 1: When CM is used for another function, this setting may be changed.
Note 2: When the CPU in system 1 is used, assign “1”.
Note 3: This data setting is required (i.e., assign 1) only when the AGENT ANYWHERE service is used in the Mul-
tiple ACDP Network configuration. In other words, this data setting takes effect only when SYS1, Index864,
bit3=1. Therefore, this data setting is not necessary (i.e., assign 0) when the AGENT ANYWHERE service
in the Single ACDP Network configuration is used.
Note 4: All FCCS nodes in the network are used for “MULTIPLE ACDPs in an FCCS Network”, this data may be
assigned using ASYDN.
Note 5: This data is required for UAP connection.
Note 6: Assign Self-node FPC for the node of which only the trunks are used for ACD functions (ACD Trunk for
FCCS.)
Note 7: Assign FPC no. of the self node.
Note 8: Assign the number of ports for status Monitor Facility Notification (SMFN). The identical data value must
be assigned at all nodes on FCCS Network. (When “Status Monitor Facility Request (SMFR), FN=126” is
used, always assign 0 (2 ports).)
ASYDL SYS1 INDEX864 b4: 0/1
0=2 ports
1=8 ports (Normal Setting)
Note 9: Although this data is valid only when INDEX864 b4=1 (8 ports), this bit must be assigned as data “0” when
INDEX864 b4=0 (2 ports). The identical data value must be assigned at all nodes on FCCS Network.
ASYDL SYS1 INDEX864 b5: 0/1
0=Status Monitor Facility Notification (SMFN) is cleared when the FCCS Link is down.
(Normal Setting)
1=Status Monitor Facility Notification (SMFN) is not cleared when the FCCS Link is
down.
Note 10:Assign the FPC no. of ACDP node using “AGENT ANYWHERE” when an FCCS Network provided MUL-
TIPLE ACDPs is also provided “AGENT ANYWHERE”. While in the network not provided “AGENT ANY-
WHERE” (actually, the node may be changed into the node provided “ACD Trunk for FCCS”) assign the
FPC no. of ACDP node using “ACD Trunk for FCCS” (In this example, FPC no. of Node D or Node F is
applied with this condition).
NodeA
NodeB
NodeC
Agent Anywhere
ACDP1
ACDP2
FCCS
FCCS
FCCS Network (Multiple ACDP configuration)
Index864 b2=1
Index864 b3=1
Index864 b2=1
Index864 b3=1
Index864 b2=0
Index864 b3=1
NodeA
NodeB
NodeC
ACDP
FCCS
FCCS
FCCS Network (Single ACDP configuration)
Index864 b2=0
Index864 b3=0
Index864 b2=0
Index864 b3=0
Index864 b2=0
Index864 b3=0
Agent Anywhere