22
© by NECTA VENDING SOLUTIONS SpA 03-2003 217 00
WHIPPING TIME
This function is used to define how long (in tenths of a
second) instant drinks are to be whipped according to the
amount to be obtained.
PROGRAMMING ACCESS PASSWORD
This function is used to enable the request for a password
to access the programming procedures.
The password is the button sequence 1 1 2 2 and cannot
be changed.
SELECTION CONFIGURATION
This function is used to determine, as an exception to the
machine configuration, which accessories should or should
not be dispensed for a specific selection.
The following is possible for each selection button (1 to 8,
excluding the pre-selection buttons):
- not dispense the cup (if the machine configuration
includes the cup, but not vice versa);
- not dispense the stirrer if the selection is unsweetened;
- not dispense sugar and stirrer for selections which are
defined as sweetened (but not dispense sugar for
selections which are defined as unsweetened).
The settings defined with the selection configuration are
used also for complete test selections.
DISCOUNT DATA
This function is used to determine by how much to increase
or decrease the price for a selection when using a ceramic
cup.
With the value set to 0 the function is disabled.
SPECIAL SALES
This function is used to enable or disable Free Vend and to
set the number of consecutive instant drinks (1 to 9; 5 by
default) that are dispensed when the “Jug facilities” func-
tion is enabled.
After these functions are enabled, do as follows:
- while in normal operating mode, press button “8” for a
few seconds;
- enter the password that was just set;
- make a selection within 10 seconds.
DIRECT FUNCTIONS
INSTALLATION
Press the installation button “3” to carry out the hydraulic
system filling operations, even with the air-break full.
RESET FAILURES
Press the failure reset button “8”; the message “Running”
is displayed for a few seconds and all present failures are
reset.