4
© by NECTA VENDING SOLUTIONS SpA 02-2004 184 02
SALES PRICES
A different programmable price can be set for each selec-
tion;
the standard setting has the same sales price for all
selections.
COIN BOX
Made of aluminised plate. Cover and lock are available as
accessories.
WATER SUPPLY
From the mains, with a pressure of 0.05 to 0.8 Mpa (0.5 -
8.5 bar).
The machine software is pre-set to control the water supply
from an internal tank (optional kit).
AVAILABLE ADJUSTMENTS
Espresso: grade of grinding, coffee and water doses
by volume.
Instant: timed coffee, instant product and water doses.
Temperature
Adjusted via software.
CONTROLS
- Presence of cups
- Presence of water
- Presence of coffee
- Position of coffee unit
- Liquid waste container empty
- Operating temperature reached
- Position of mobile dispensing spouts
SAFETY DEVICES
- Door switch
- Manual-reset boiler safety thermostat
- Air-break float jammed
- Overflow solenoid valve
- Float for full liquid waste container
- Boiler sensor short-circuit/failure control
- Timer protection for:
Pump
Coffee unit ratiomotor
Coffee dispensing
Coffee grinder
Cup column shift motor
- Overheating protection for:
Doser units
Coffee unit ratiomotor
Coffee release magnets
Pump
Mixers
Coffee grinder motor
- Fuse protection for:
Electronic card and coin mechanism power sup-
ply transformer
(primary and secondary windings)
CAPACITY OF CONTAINERS
Coffee beans 3.2 Kg
Stirrers Approx. 450
Cups Approx. 490
According to the model, containers with 3.5 or 11-litre
capacity or a two compartment container can be fitted for
instant products. Products quantities are indicated in the
following table:
The effective quantity of product can differ from what is
indicated, according to the density of the various products.
POWER CONSUMPTION
The machine power consumption depends on many fac-
tors, such as the temperature and ventilation of the room
where it is installed, the inlet water and boiler temperature,
etc.
With an ambient temperature of 22 °C the following power
consumption levels resulted:
The above power consumption calculated from average
data should only be taken as an indication.
reniatnoCtnemtrapmoC
)sertil(ezis5.4115.37
gKeeffoctnatsnI2.19.08.1
gKkliM3.12.30.10.2
gKetalocohC1.35.74.28.4
gKraguS2.43.36.6
gKaetnomeL3.44.38.6
osserpsEtnatsnI
snoitceles03htiwtnuomaknirdl62.1l22.1
erutarepmetknirdegarevaC°2.18C°7.37
noitpmusnocrewoP
erutarepmetgnitarepohcaerothW17.15hW1.471
ybdnatsfoh42hW2012hW4281
ruoh/snoitceles03hW7.132hW5.861