FilterBox
Press ESC for menu
Time to service:
3000 Hours
Idling
Press OK to select
1. Start/stop Settings
2. Maintenance
-
-
-
-
Press OK to change
1. Welding clamp: On
2. Air tool flow: On
3. Receptacle: On
-
-
-
Press OK to edit
1. Fan off delay: 1
2. Auto. cleaning: Off
3. Timer cleaning: On
4. Tmr.clean interval: 0
5. A./M. fan start
-
Press ESC to return
Enter unlock code
>
15
Press ESC for menu
Time to service:
3000 Hours
Idling
Press OK to select
1. Start/stop Settings
2. Maintenance
-
-
-
>
-
Press OK to edit
1. Fan off delay: 1
2. Auto. cleaning: On
3. Timer cleaning: On
4. Tmr.clean interval: 0
5. A./M. fan start
-
>
Press OK to edit
1. Fan off delay: 45
2. Auto. cleaning: Off
3. Timer cleaning: On
4. Tmr.clean interval: 0
5. A./M. fan start
-
*
2. Auto. cleaning: [ON/OFF]
16
Press ESC for menu
Time to service:
3000 Hours
Idling
Press OK to select
1. Start/stop Settings
2. Maintenance
-
-
-
>
-
Press OK to edit
1. Fan off delay: 45
2. Auto. cleaning: On
3. Timer cleaning: On
4. Tmr.clean interval: 30
5. A./M. fan start
-
*
3. Timer cleaning: [ON/OFF]
4. Tmr.clean interval: [10-60 min]
17
17